| Assessment Year | 1990 |
|---|---|
| Principal Product | ZINC CASTINGS |
| NAICS |
n/a
|
| SIC | 3432: Plumbing Fixture Fittings and Trim |
| Sales Range | $10 M to 50M |
| # of Employees | 230 |
| Plant Area |
n/a
|
| Annual Production | 81,000,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $263,831 | 5,468,054 |
kWh
|
$0.048 |
| LPG | $160,067 | 47,642 |
MMBtu
|
$3.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $50,972 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,564 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
|---|---|---|---|---|---|---|
| 01 | 3.4151: Minimize water usage | $4,564 | $4,200 |
$4,564
103,165
kWh
|
- | |
| 02 | 2.5194: Redesign process | $27,328 | $30,000 |
$27,328
618,113
kWh
|
- | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $19,080 | $70,000 | - |
$19,080
-
MMBtu
|
|
| TOTAL RECOMMENDED | $50,972 | $104,200 |
$31,892
721,278
kWh
|
$19,080
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,564 | $4,200 |
$4,564
103,165
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs