| Assessment Year | 1990 |
|---|---|
| Principal Product | INJECTION MOLDED PARTS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 84 |
| Plant Area |
n/a
|
| Annual Production | 3,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $155,921 | 2,953,986 |
kWh
|
$0.053 |
| Natural Gas | $3,787 | 720 |
MMBtu
|
$5.26 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $30,862 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $12,000 | - |
$12,000
-
kWh
|
- | |
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,890 | - |
$4,890
-
kWh
|
- | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,175 | - |
$2,175
-
kWh
|
- | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,611 | - |
$7,964
221,864
kWh
|
$(-1,353.0)
-
MMBtu
|
|
| 05 | 2.4239: Eliminate or reduce compressed air usage | $5,186 | $10,000 |
$5,186
119,871
kWh
|
- | |
| TOTAL RECOMMENDED | $30,862 | $10,000 |
$32,215
341,735
kWh
|
$(-1,353.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs