| Assessment Year | 1989 |
|---|---|
| Principal Product | PLASTIC INJECTION MOLDS |
| NAICS |
n/a
|
| SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
| Sales Range | $5 M to 10M |
| # of Employees | 52 |
| Plant Area |
n/a
|
| Annual Production | 40
pieces
|
| Production Hrs. Annual | 4,500
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $40,084 | 749,414 |
kWh
|
$0.053 |
| LPG | $3,200 | 451 |
MMBtu
|
$7.10 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,025 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $525 | - |
$733
-
kWh
|
- | $(-208.0) | |
| 02 | 2.3191: Use demand controller or load shedder | $2,200 | $2,000 |
$2,200
-
kWh
|
- | - | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $700 | $80 |
$640
12,016
kWh
|
- | $60 | |
| 04 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $600 | $5,445 |
$66
1,172
kWh
|
$534
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $4,025 | $7,525 |
$3,639
13,188
kWh
|
$534
-
MMBtu
|
$(-148.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs