| Assessment Year | 1988 |
|---|---|
| Principal Product | VACUUM FORMED PLASTICS |
| NAICS |
n/a
|
| SIC | 3082: Unsupported Plastics Profile Shapes |
| Sales Range | $1 M to 5M |
| # of Employees | 40 |
| Plant Area |
n/a
|
| Annual Production | 25,000
pieces
|
| Production Hrs. Annual | 2,400
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $67,358 | 540,739 |
kWh
|
$0.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,371 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,371 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.5194: Redesign process | $3,796 | $1,000 |
$3,796
34,291
kWh
|
|
| 02 | 2.2444: Use hot process fluids to preheat incoming process fluids | $1,575 | $1,000 |
$1,575
11,137
kWh
|
|
| TOTAL RECOMMENDED | $5,371 | $2,000 |
$5,371
45,428
kWh
|
||
| TOTAL IMPLEMENTED | $5,371 | $2,000 |
$5,371
45,428
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs