Assessment Year | 1988 |
---|---|
Principal Product | APPLIANCE PARTS |
NAICS |
n/a
|
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 14 |
Plant Area |
n/a
|
Annual Production | 13,000,000
pieces
|
Production Hrs. Annual | 4,335
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $8,116 | 97,011 |
kWh
|
$0.084 |
Natural Gas | $773 | 158 |
MMBtu
|
$4.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,030 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $350 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $182 | - |
$219
3,810
kWh
|
$(-37.0)
-
MMBtu
|
- | |
02 | 2.3191: Use demand controller or load shedder | $680 | - |
$680
-
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $168 | $64 |
$216
3,810
kWh
|
$(-37.0)
-
MMBtu
|
$(-11.0) | |
TOTAL RECOMMENDED | $1,030 | $64 |
$1,115
7,620
kWh
|
$(-74.0)
-
MMBtu
|
$(-11.0) | ||
TOTAL IMPLEMENTED | $350 | $64 |
$435
7,620
kWh
|
$(-74.0)
-
MMBtu
|
$(-11.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs