| Assessment Year | 1988 |
|---|---|
| Principal Product | ACOUSTICAL PANELS & DECK |
| NAICS |
n/a
|
| SIC | 2435: Hardwood Veneer and Plywood |
| Sales Range | $5 M to 10M |
| # of Employees | 100 |
| Plant Area |
n/a
|
| Annual Production | 14,000
thousand feet
|
| Production Hrs. Annual | 1,600
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $102,899 | 1,648,007 |
kWh
|
$0.062 |
| Natural Gas | $128,125 | 47,005 |
MMBtu
|
$2.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,007 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,943 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,175 | $2,800 |
$2,175
41,618
kWh
|
- | - | |
| 02 | 2.2437: Recover waste heat from equipment | $621 | $3,000 | - |
$249
-
MMBtu
|
$372 | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $768 | $1,000 | - |
$768
-
MMBtu
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $4,290 | $7,000 | - |
$4,290
-
MMBtu
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $20,153 | $80,000 | - |
$20,153
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $28,007 | $93,800 |
$2,175
41,618
kWh
|
$25,460
-
MMBtu
|
$372 | ||
| TOTAL IMPLEMENTED | $2,943 | $3,800 |
$2,175
41,618
kWh
|
$768
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs