| Assessment Year | 1988 |
|---|---|
| Principal Product | CORRUGATED PAPER PCKGING |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 103 |
| Plant Area |
n/a
|
| Annual Production | 22,000
ton
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $120,416 | 2,167,057 |
kWh
|
$0.056 |
| Natural Gas | $96,892 | 27,048 |
MMBtu
|
$3.58 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,052 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $24,052 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $2,007 | $900 |
$617
11,137
kWh
|
$1,390
-
MMBtu
|
- | |
| 02 | 3.4157: Replace water cooling on processes with air cooling | $15,536 | $20,000 |
$2,245
20,809
kWh
|
$886
-
MMBtu
|
$12,405 | |
| 03 | 2.2511: Insulate bare equipment | $875 | $805 | - |
$875
-
MMBtu
|
- | |
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $4,830 | $8,000 | - |
$4,830
-
MMBtu
|
- | |
| 05 | 2.7494: Install storm windows and doors | $804 | $700 | - |
$804
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $24,052 | $30,405 |
$2,862
31,946
kWh
|
$8,785
-
MMBtu
|
$12,405 | ||
| TOTAL IMPLEMENTED | $24,052 | $30,405 |
$2,862
31,946
kWh
|
$8,785
-
MMBtu
|
$12,405 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs