Assessment Year | 1987 |
---|---|
Principal Product | ALUMINUM EXTRUSIONS |
NAICS |
n/a
|
SIC | 3354: Aluminum Extruded Products |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
n/a
|
Annual Production | 8,000,000
pieces
|
Production Hrs. Annual | 5,500
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $202,813 | 3,174,678 |
kWh
|
$0.064 |
Natural Gas | $128,331 | 23,544 |
MMBtu
|
$5.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,115 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,115 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3511: Use plant owned transformers or lease transformers | $20,472 | $36,000 |
$20,472
-
kWh
|
- | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,814 | - |
$2,814
-
kWh
|
- | |
03 | 2.2531: Re-size charging openings or add movable cover or door | $1,600 | $250 | - |
$1,600
-
MMBtu
|
|
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $4,229 | $40 |
$170
5,862
kWh
|
$4,059
-
MMBtu
|
|
TOTAL RECOMMENDED | $29,115 | $36,290 |
$23,456
5,862
kWh
|
$5,659
-
MMBtu
|
||
TOTAL IMPLEMENTED | $29,115 | $36,290 |
$23,456
5,862
kWh
|
$5,659
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs