Assessment Year 1987
Principal Product NICKEL & ZINC PLATING
NAICS
n/a
SIC 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring
Sales Range $5
M
to 10
M
# of Employees 75
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 6,240
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $129,718 2,468,347
kWh
Natural Gas $76,539 15,872
MMBtu
Fuel Oil #2 $51,681 15,674
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $10,718 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $10,718

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Fuel Oil #2 Savings Administrative Changes Savings
01 2.2414: Use waste heat from hot flue gases to preheat $9,497 $15,000 - $5,242
-
MMBtu
$4,255
-
MMBtu
-
02 2.1131: Repair faulty insulation in furnaces, boilers, etc $1,021 - - $564
-
MMBtu
$457
-
MMBtu
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $200 $60 $86
2,052
kWh
- - $114
TOTAL RECOMMENDED $10,718 $15,060 $86
2,052
kWh
$5,806
-
MMBtu
$4,712
-
MMBtu
$114
TOTAL IMPLEMENTED $10,718 $15,060 $86
2,052
kWh
$5,806
-
MMBtu
$4,712
-
MMBtu
$114