Assessment Year | 1987 |
---|---|
Principal Product | INJECTION MOLDED PARTS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 70 |
Plant Area |
n/a
|
Annual Production | 1,800
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $56,839 | 1,056,858 |
kWh
|
$0.054 |
Natural Gas | $6,686 | 1,292 |
MMBtu
|
$5.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,699 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,055 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1321: Replace fossil fuel equipment with electrical equipment | $644 | $3,000 |
$(-454.0)
(-7,620)
kWh
|
$1,098
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,469 | $1,070 |
$2,411
50,117
kWh
|
$(-140.0)
-
MMBtu
|
$198 | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,586 | - |
$1,586
7,034
kWh
|
- | - | |
TOTAL RECOMMENDED | $4,699 | $4,070 |
$3,543
49,531
kWh
|
$958
-
MMBtu
|
$198 | ||
TOTAL IMPLEMENTED | $4,055 | $1,070 |
$3,997
57,151
kWh
|
$(-140.0)
-
MMBtu
|
$198 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs