| Assessment Year | 1987 |
|---|---|
| Principal Product | WELDING WIRES & FLUXES |
| NAICS |
n/a
|
| SIC | 3398: Metal Heat Treating |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
n/a
|
| Annual Production | 3,600,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $369,892 | 5,623,095 |
kWh
|
$0.066 |
| Natural Gas | $54,667 | 10,639 |
MMBtu
|
$5.14 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,278 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $31,281 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $26,035 | $30,000 |
$32,616
577,081
kWh
|
$(-6,581.0)
-
MMBtu
|
- | |
| 02 | 2.3212: Optimize plant power factor | $4,712 | $12,000 |
$4,712
-
kWh
|
- | - | |
| 03 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $1,245 | - |
$1,844
53,634
kWh
|
$(-599.0)
-
MMBtu
|
- | |
| 04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $534 | $6,000 |
$422
12,309
kWh
|
- | $112 | |
| 05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,752 | - |
$7,152
-
kWh
|
- | $(-1,400.0) | |
| TOTAL RECOMMENDED | $38,278 | $48,000 |
$46,746
643,024
kWh
|
$(-7,180.0)
-
MMBtu
|
$(-1,288.0) | ||
| TOTAL IMPLEMENTED | $31,281 | $48,000 |
$37,750
589,390
kWh
|
$(-6,581.0)
-
MMBtu
|
$112 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs