| Assessment Year | 1987 |
|---|---|
| Principal Product | PAPER CONVERTING PRODCTS |
| NAICS |
n/a
|
| SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
n/a
|
| Annual Production | 4,500,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $143,181 | 1,919,695 |
kWh
|
$0.075 |
| Natural Gas | $264,815 | 56,751 |
MMBtu
|
$4.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $42,857 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,163 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7492: Use proper thickness of insulation on building envelope | $2,972 | $2,565 | - |
$2,972
-
MMBtu
|
- | |
| 02 | 2.2414: Use waste heat from hot flue gases to preheat | $18,458 | $30,000 | - |
$18,458
-
MMBtu
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,151 | $1,232 |
$2,480
38,980
kWh
|
$(-305.0)
-
MMBtu
|
$976 | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $11,040 | $24,000 | - |
$11,040
-
MMBtu
|
- | |
| 05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $7,236 | - |
$7,236
-
kWh
|
- | - | |
| TOTAL RECOMMENDED | $42,857 | $57,797 |
$9,716
38,980
kWh
|
$32,165
-
MMBtu
|
$976 | ||
| TOTAL IMPLEMENTED | $17,163 | $27,797 |
$2,480
38,980
kWh
|
$13,707
-
MMBtu
|
$976 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs