Assessment Year | 1987 |
---|---|
Principal Product | AUTO SAFETY & LIGHTING |
NAICS |
n/a
|
SIC | 3647: Vehicular Lighting Equipment |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 6,000,000
pieces
|
Production Hrs. Annual | 2,032
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $101,702 | 1,421,454 |
kWh
|
$0.072 |
Natural Gas | $89,342 | 17,649 |
MMBtu
|
$5.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,297 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,297 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $2,781 | $2,200 |
$2,781
-
kWh
|
- | - | |
02 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $1,298 | $1,000 | - |
$259
-
MMBtu
|
$1,039 | |
03 | 2.7494: Install storm windows and doors | $2,611 | $2,160 | - |
$2,611
-
MMBtu
|
- | |
04 | 2.2136: Install / repair insulation on steam lines | $228 | $360 | - |
$228
-
MMBtu
|
- | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $4,248 | $6,000 | - |
$4,248
-
MMBtu
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,131 | $14,688 |
$7,414
109,027
kWh
|
$(-1,488.0)
-
MMBtu
|
$2,205 | |
TOTAL RECOMMENDED | $19,297 | $26,408 |
$10,195
109,027
kWh
|
$5,858
-
MMBtu
|
$3,244 | ||
TOTAL IMPLEMENTED | $19,297 | $26,408 |
$10,195
109,027
kWh
|
$5,858
-
MMBtu
|
$3,244 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs