| Assessment Year | 1986 |
|---|---|
| Principal Product | REINFORCED ELECTRICAL GRATES |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 256 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $248,707 | 3,740,914 |
kWh
|
$0.066 |
| Natural Gas | $134,541 | 28,404 |
MMBtu
|
$4.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $36,362 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,975 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Natural Gas Savings |
|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $6,538 | $5,000 |
$6,538
-
MMBtu
|
|
| 02 | 2.7421: Reduce glazed areas in buildings | $3,993 | $20,000 |
$3,993
-
MMBtu
|
|
| 03 | 2.2437: Recover waste heat from equipment | $5,444 | $1,000 |
$5,444
-
MMBtu
|
|
| 04 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $20,387 | $50,000 |
$20,387
-
MMBtu
|
|
| TOTAL RECOMMENDED | $36,362 | $76,000 |
$36,362
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $15,975 | $26,000 |
$15,975
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs