Assessment Year | 1986 |
---|---|
Principal Product | REINFORCED ELECTRICAL GRATES |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 256 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $248,707 | 3,740,914 |
kWh
|
$0.066 |
Natural Gas | $134,541 | 28,404 |
MMBtu
|
$4.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $36,362 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,975 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Natural Gas Savings |
---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $6,538 | $5,000 |
$6,538
-
MMBtu
|
|
02 | 2.7421: Reduce glazed areas in buildings | $3,993 | $20,000 |
$3,993
-
MMBtu
|
|
03 | 2.2437: Recover waste heat from equipment | $5,444 | $1,000 |
$5,444
-
MMBtu
|
|
04 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $20,387 | $50,000 |
$20,387
-
MMBtu
|
|
TOTAL RECOMMENDED | $36,362 | $76,000 |
$36,362
-
MMBtu
|
||
TOTAL IMPLEMENTED | $15,975 | $26,000 |
$15,975
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs