Assessment Year | 1986 |
---|---|
Principal Product | PRECISION MEASURING INSTRUMENTS |
NAICS |
n/a
|
SIC | 3545: Cutting Tools, Machine Tool Accessories, and Machinists' Precision Measuring Devices |
Sales Range | $50 M to 100M |
# of Employees | 450 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $452,217 | 8,949,883 |
kWh
|
$0.051 |
Natural Gas | $98,085 | 17,426 |
MMBtu
|
$5.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,447 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,631 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $11,737 | - |
$12,257
-
kWh
|
- | $(-520.0) | |
02 | 2.4322: Use or replace with energy efficient substitutes | $4,588 | $10,000 |
$4,588
115,768
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,491 | $38,950 |
$18,491
270,809
kWh
|
- | - | |
04 | 2.7492: Use proper thickness of insulation on building envelope | $3,631 | $10,070 | - |
$3,631
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $38,447 | $59,020 |
$35,336
386,577
kWh
|
$3,631
-
MMBtu
|
$(-520.0) | ||
TOTAL IMPLEMENTED | $3,631 | $10,070 | - |
$3,631
-
MMBtu
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs