Assessment Year | 1985 |
---|---|
Principal Product | CORRUGATED BOXES |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $1 M to 5M |
# of Employees | 56 |
Plant Area |
n/a
|
Annual Production | 60,000
thousand feet
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $35,043 | 592,907 |
kWh
|
$0.059 |
Natural Gas | $60,548 | 11,899 |
MMBtu
|
$5.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,637 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,637 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.5123: Reduce fluid flow rates | $513 | $150 |
$396
7,620
kWh
|
$117
-
MMBtu
|
|
02 | 2.7494: Install storm windows and doors | $1,368 | $1,226 | - |
$1,368
-
MMBtu
|
|
03 | 2.2414: Use waste heat from hot flue gases to preheat | $12,756 | $25,000 | - |
$12,756
-
MMBtu
|
|
04 | 2.2437: Recover waste heat from equipment | $4,000 | $13,000 | - |
$4,000
-
MMBtu
|
|
TOTAL RECOMMENDED | $18,637 | $39,376 |
$396
7,620
kWh
|
$18,241
-
MMBtu
|
||
TOTAL IMPLEMENTED | $14,637 | $26,376 |
$396
7,620
kWh
|
$14,241
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs