Assessment Year | 1983 |
---|---|
Principal Product | TOOLS,DIES,SPECIAL MACHINE PARTS |
NAICS |
n/a
|
SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
Sales Range | $5 M to 10M |
# of Employees | 99 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $28,165 | 408,558 |
kWh
|
$0.069 |
Other Energy | $26,586 | 2,703 |
MMBtu
|
$9.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,671 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,125 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Energy Savings |
---|---|---|---|---|---|---|
01 | 2.7492: Use proper thickness of insulation on building envelope | $9,144 | $18,000 | - |
$9,144
-
MMBtu
|
|
02 | 2.1391: Replace purchased steam with electric heating | $3,546 | $2,000 |
$(-506.0)
(-6,448)
kWh
|
$4,052
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $583 | $172 |
$793
9,379
kWh
|
$(-210.0)
-
MMBtu
|
|
04 | 2.7494: Install storm windows and doors | $3,398 | $2,560 | - |
$3,398
-
MMBtu
|
|
TOTAL RECOMMENDED | $16,671 | $22,732 |
$287
2,931
kWh
|
$16,384
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,125 | $20,732 |
$793
9,379
kWh
|
$12,332
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs