| Assessment Year | 1983 |
|---|---|
| Principal Product | WIRE SHELVES FOR APPLIANCES |
| NAICS |
n/a
|
| SIC | 3496: Miscellaneous Fabricated Wire Products |
| Sales Range | $5 M to 10M |
| # of Employees | 89 |
| Plant Area |
n/a
|
| Annual Production | 3,500,000
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $227,047 | 2,684,056 |
kWh
|
$0.085 |
| Natural Gas | $181,324 | 39,921 |
MMBtu
|
$4.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,509 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,885 | $200 |
$2,885
9,965
kWh
|
- | |
| 02 | 2.7494: Install storm windows and doors | $4,277 | $8,800 | - |
$4,277
-
MMBtu
|
|
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,757 | $250 | - |
$3,757
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,590 | $1,300 |
$3,283
47,479
kWh
|
$(-693.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $13,509 | $10,550 |
$6,168
57,444
kWh
|
$7,341
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs