Assessment Year | 1983 |
---|---|
Principal Product | POWDERED METAL PARTS |
NAICS |
n/a
|
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,200
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $206,400 | 4,384,818 |
kWh
|
$0.047 |
Natural Gas | $20,875 | 4,549 |
MMBtu
|
$4.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,324 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,364 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,990 | $627 |
$1,990
39,566
kWh
|
|
02 | 2.7494: Install storm windows and doors | $1,451 | $2,000 |
$1,451
31,067
kWh
|
|
03 | 2.7492: Use proper thickness of insulation on building envelope | $2,364 | $3,680 |
$2,364
50,410
kWh
|
|
04 | 2.2437: Recover waste heat from equipment | $6,519 | $40,000 |
$6,519
138,921
kWh
|
|
TOTAL RECOMMENDED | $12,324 | $46,307 |
$12,324
259,964
kWh
|
||
TOTAL IMPLEMENTED | $2,364 | $3,680 |
$2,364
50,410
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs