| Assessment Year | 1983 |
|---|---|
| Principal Product | POWDERED METAL PARTS |
| NAICS |
n/a
|
| SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,200
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $206,400 | 4,384,818 |
kWh
|
$0.047 |
| Natural Gas | $20,875 | 4,549 |
MMBtu
|
$4.59 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,324 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,364 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,990 | $627 |
$1,990
39,566
kWh
|
|
| 02 | 2.7494: Install storm windows and doors | $1,451 | $2,000 |
$1,451
31,067
kWh
|
|
| 03 | 2.7492: Use proper thickness of insulation on building envelope | $2,364 | $3,680 |
$2,364
50,410
kWh
|
|
| 04 | 2.2437: Recover waste heat from equipment | $6,519 | $40,000 |
$6,519
138,921
kWh
|
|
| TOTAL RECOMMENDED | $12,324 | $46,307 |
$12,324
259,964
kWh
|
||
| TOTAL IMPLEMENTED | $2,364 | $3,680 |
$2,364
50,410
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs