| Assessment Year | 1982 |
|---|---|
| Principal Product | SPECIAL IND. MECHINERY |
| NAICS |
n/a
|
| SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 72 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 2,990
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $25,092 | 344,959 |
kWh
|
$0.073 |
| LPG | $2,151 | 256 |
MMBtu
|
$8.40 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | LPG Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $422 | $140 |
$443
7,327
kWh
|
- |
$(-21.0)
-
MMBtu
|
|
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $6,865 | $5,000 |
$8,298
84,115
kWh
|
$(-1,433.0)
-
MMBtu
|
- | |
| 03 | 2.6121: Reduce hot water temperature to the minimum required | $153 | - |
$153
4,982
kWh
|
- | - | |
| TOTAL RECOMMENDED | $7,440 | $5,140 |
$8,894
96,424
kWh
|
$(-1,433.0)
-
MMBtu
|
$(-21.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs