Assessment Year | 1982 |
---|---|
Principal Product | HYDRAULIC TUBE FITTINGS |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 328 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $277,908 | 6,616,061 |
kWh
|
$0.042 |
Natural Gas | $46,078 | 11,875 |
MMBtu
|
$3.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,790 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,478 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6121: Reduce hot water temperature to the minimum required | $460 | - |
$460
3,810
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,295 | $753 |
$3,295
70,340
kWh
|
- | |
03 | 2.7444: Close holes and openings in building such as broken windows | $4,219 | $6,160 | - |
$4,219
-
MMBtu
|
|
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,504 | $900 | - |
$4,504
-
MMBtu
|
|
05 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $3,312 | $1,500 | - |
$3,312
-
MMBtu
|
|
TOTAL RECOMMENDED | $15,790 | $9,313 |
$3,755
74,150
kWh
|
$12,035
-
MMBtu
|
||
TOTAL IMPLEMENTED | $12,478 | $7,813 |
$3,755
74,150
kWh
|
$8,723
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs