| Assessment Year | 1982 |
|---|---|
| Principal Product | PLASTIC SHEETS & SHAPES |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 60 |
| Plant Area |
n/a
|
| Annual Production | 100,000
lb
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $24,193 | 312,427 |
kWh
|
$0.077 |
| Natural Gas | $12,660 | 3,418 |
MMBtu
|
$3.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,889 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,776 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6121: Reduce hot water temperature to the minimum required | $70 | $150 |
$46
586
kWh
|
$24
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $938 | $258 |
$938
12,603
kWh
|
- | |
| 03 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $4,933 | $2,000 |
$4,933
51,876
kWh
|
- | |
| 04 | 2.7243: Improve air circulation with destratification fans / other methods | $1,768 | $1,700 | - |
$1,768
-
MMBtu
|
|
| 05 | 2.7314: Reduce ventilation air | $180 | $150 |
$100
1,172
kWh
|
$80
-
MMBtu
|
|
| TOTAL RECOMMENDED | $7,889 | $4,258 |
$6,017
66,237
kWh
|
$1,872
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,776 | $2,108 |
$984
13,189
kWh
|
$1,792
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs