| Assessment Year | 2026 |
|---|---|
| Principal Product | Electromagnetic Coils |
| NAICS | 335314: Relay and Industrial Control Manufacturing |
| SIC | 3677: Electronic Coils, Transformers, and Other Inductors |
| Sales Range | $10 M to 50M |
| # of Employees | 109 |
| Plant Area |
30,000
ft2
|
| Annual Production | 1,600,000
units
|
| Production Hrs. Annual | 4,316
hrs
|
| Location (State) | Connecticut |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $133,090 | 662,374 |
kWh
|
$0.20 |
| Electricity Demand | $46,677 | 3,079 |
kW-mo/yr
|
$15.16 |
| Electricity Fees | $12,713 | - |
|
- |
| Natural Gas | $14,040 | 1,597 |
MMBtu
|
$8.79 |
| TOTAL YEARLY COSTS | $206,520 | |||
| RECOMMENDED SAVINGS* | $1,585,475 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,241 | $358 |
$1,957
9,739
kWh
|
$284
-
kW-mo/yr
|
- | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $786 | - |
$633
3,151
kWh
|
$153
-
kW-mo/yr
|
- | - | |
| 03 | 2.7134: Use photocell controls | $1,925 | $1,400 |
$1,855
9,233
kWh
|
$69
-
kW-mo/yr
|
- | - | |
| 04 | 2.7135: Install occupancy sensors | $1,473 | $2,600 |
$1,432
7,161
kWh
|
$41
-
kW-mo/yr
|
- | - | |
| 05 | 3.2176: Increase use of automation | $200,000 | $600,000 | - | - | $200,000 | - | |
| 06 | 3.2176: Increase use of automation | $1,200,000 | $340,000 | - | - | $1,200,000 | - | |
| 07 | 4.426: Modify workload | $179,050 | $86,700 | - | - | - | $179,050 | |
| TOTAL RECOMMENDED | $1,585,475 | $1,031,058 |
$5,877
29,284
kWh
|
$547
-
kW-mo/yr
|
$1,400,000 | $179,050 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs