| Assessment Year | 2025 |
|---|---|
| Principal Product | Asphalt |
| NAICS | 324121: Asphalt Paving Mixture and Block Manufacturing |
| SIC | 2951: Asphalt Paving Mixtures and Blocks |
| Sales Range | $5 M to 10M |
| # of Employees | 6 |
| Plant Area |
447,376
ft2
|
| Annual Production | 84,119
ton
|
| Production Hrs. Annual | 1,900
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $31,088 | 267,120 |
kWh
|
$0.12 |
| Electricity Demand | $57,088 | 2,552 |
kW-mo/yr
|
$22.37 |
| Electricity Fees | $2,199 | - |
|
- |
| LPG | $200,938 | 17,735 |
MMBtu
|
$11.33 |
| Other Gas | $119,086 | 5,413 |
MMBtu
|
$22.00 |
| TOTAL YEARLY COSTS | $410,399 | |||
| RECOMMENDED SAVINGS* | $177,043 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Gas Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $677 | $370 |
$314
2,700
kWh
|
$362
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.2511: Insulate bare equipment | $19,982 | $9,655 | - | - | - |
$19,982
-
MMBtu
|
- | - | |
| 03 | 2.9114: Use solar heat to make electricty | $25,271 | $169,615 |
$25,271
170,177
kWh
|
- | - | - | - | - | |
| 04 | 2.8114: Change rate schedules or other changes in utility service | $102,262 | $420,000 | - | - | - |
$46,758
-
MMBtu
|
$(-50,700.0) | $106,204 | |
| 05 | 2.6126: Keep solid fuels / raw materials dry | $23,748 | $104,000 | - | - |
$23,748
-
MMBtu
|
- | - | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,176 | - |
$23
199
kWh
|
$1,153
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.4322: Use or replace with energy efficient substitutes | $3,927 | $15,750 |
$1,187
10,193
kWh
|
$2,740
-
kW-mo/yr
|
- | - | - | - | |
| TOTAL RECOMMENDED | $177,043 | $719,390 |
$26,795
183,269
kWh
|
$4,256
-
kW-mo/yr
|
$23,748
-
MMBtu
|
$66,740
-
MMBtu
|
$(-50,700.0) | $106,204 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Gas Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||