Assessment Year | 2024 |
---|---|
Principal Product | Semiconductor wafers |
NAICS | 334413: Semiconductor and Related Device Manufacturing |
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $5 M to 10M |
# of Employees | 500 |
Plant Area |
92,600
ft2
|
Annual Production | 130,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,034,443 | 9,948,743 |
kWh
|
$0.10 |
Electricity Demand | $356,769 | 15,359 |
kW-mo/yr
|
$23.23 |
Natural Gas | $459,494 | 53,316 |
MMBtu
|
$8.62 |
TOTAL YEARLY COSTS | $1,850,705 | |||
RECOMMENDED SAVINGS* | $635,086 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $19,662 | $1,600 |
$15,055
144,761
kWh
|
$4,607
-
kW-mo/yr
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $159,604 | $5,236 |
$98,630
948,361
kWh
|
$30,179
-
kW-mo/yr
|
$30,796
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,767 | $1,553 |
$1,239
11,914
kWh
|
$379
-
kW-mo/yr
|
- | $149 | |
04 | 2.7135: Install occupancy sensors | $510 | $218 |
$510
4,380
kWh
|
- | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $73,494 | $29,062 |
$56,275
541,105
kWh
|
$17,219
-
kW-mo/yr
|
- | - | |
06 | 2.2511: Insulate bare equipment | $3,536 | $1,750 | - | - |
$3,536
-
MMBtu
|
- | |
07 | 2.2136: Install / repair insulation on steam lines | $294 | $139 | - | - |
$294
-
MMBtu
|
- | |
08 | 2.2622: Replace existing chiller with high efficiency model | $240,811 | $2,527,500 |
$184,391
1,772,991
kWh
|
$56,420
-
kW-mo/yr
|
- | - | |
09 | 2.7232: Replace existing hvac unit with high efficiency model | $80,097 | $301,647 |
$61,331
589,723
kWh
|
$18,766
-
kW-mo/yr
|
- | - | |
10 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $55,311 | $819,496 |
$268,843
2,585,030
kWh
|
$6,855
-
kW-mo/yr
|
$(-220,387.0)
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $635,086 | $3,688,201 |
$686,274
6,598,266
kWh
|
$134,424
-
kW-mo/yr
|
$(-185,761.3)
-
MMBtu
|
$149 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs