Assessment Year | 1999 |
---|---|
Principal Product | Roasted Coffee |
NAICS |
n/a
|
SIC | 2095: Roasted Coffee |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
31,000
ft2
|
Annual Production | 4,500,000
lb
|
Production Hrs. Annual | 2,654
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $37,016 | 805,100 |
kWh
|
$0.046 |
Electricity Demand | $14,156 | 2,556 |
kW-mo/yr
|
$5.54 |
Electricity Fees | $7,052 | - |
|
- |
Natural Gas | $37,280 | 5,351 |
MMBtu
|
$6.97 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,457 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,924 | $25,775 |
$3,188
69,461
kWh
|
$1,736
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $159 | $20 |
$159
3,517
kWh
|
- | - | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $1,104 | $130 |
$168
3,517
kWh
|
- |
$936
-
MMBtu
|
- | |
04 | 4.821: Pay bills on time to avoid late fees | $1,270 | - | - | - | - | $1,270 | |
TOTAL RECOMMENDED | $7,457 | $25,925 |
$3,515
76,495
kWh
|
$1,736
-
kW-mo/yr
|
$936
-
MMBtu
|
$1,270 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs