Assessment Year | 2024 |
---|---|
Principal Product | Machined parts |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 16 |
Plant Area |
12,500
ft2
|
Annual Production | 50,000
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,442 | 541,597 |
kWh
|
$0.093 |
Electricity Demand | $70,249 | 1,688 |
kW-mo/yr
|
$41.61 |
Electricity Fees | $2,839 | - |
|
- |
Fuel Oil #2 | $6,609 | 236 |
MMBtu
|
$27.97 |
TOTAL YEARLY COSTS | $130,138 | |||
RECOMMENDED SAVINGS* | $14,623 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8123: Pay utility bills on time | $829 | - | - | - | $829 | - | - | |
02 | 2.8118: Check for accuracy of utility / power meters | $614 | - | - | - | $614 | - | - | |
03 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $1,916 | $36,122 |
$164
1,765
kWh
|
- | - | - |
$1,751
-
MMBtu
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $972 | $75 |
$517
5,549
kWh
|
$455
-
kW-mo/yr
|
- | - | - | |
05 | 2.7261: Install timers and/or thermostats | $1,166 | $2,183 |
$58
624
kWh
|
- | - | - |
$1,108
-
MMBtu
|
|
06 | 2.1221: Replace obsolete burners with more efficient ones | $4,482 | $16,784 | - | - | - |
$(-2,128.0)
-
MMBtu
|
$6,610
-
MMBtu
|
|
07 | 2.7232: Replace existing hvac unit with high efficiency model | $4,645 | $32,845 |
$(-1,218.0)
(-13,083)
kWh
|
$(-745.7)
-
kW-mo/yr
|
- | - |
$6,609
-
MMBtu
|
|
TOTAL RECOMMENDED | $14,623 | $88,009 |
$(-478.9)
(-5,144)
kWh
|
$(-290.4)
-
kW-mo/yr
|
$1,443 |
$(-2,128.0)
-
MMBtu
|
$16,077
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Fuel Oil #2 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs