Assessment Year 2012
Principal Product Fabrics
NAICS 313210: Broadwoven Fabric Mills
SIC 2211: Broadwoven Fabric Mills, Cotton
Sales Range $50
M
to 100
M
# of Employees 300
Plant Area 340,000
ft2
Annual Production 15,000,000
units
Production Hrs. Annual 8,568
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $569,083 12,837,664
kWh
Electricity Demand $198,066 28,853
kW-mo/yr
Natural Gas $102,845 10,243
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $77,608 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $26,818 $40,135 $21,334
481,247
kWh
$4,627
-
kW-mo/yr
$857
02 2.7142: Utilize higher efficiency lamps and/or ballasts $18,324 $82,319 $14,580
328,894
kWh
$3,158
-
kW-mo/yr
$586
03 2.7135: Install occupancy sensors $11,129 $5,264 $10,773
243,026
kWh
- $356
04 2.4231: Reduce the pressure of compressed air to the minimum required $8,268 $960 $6,010
135,566
kWh
$1,994
-
kW-mo/yr
$264
05 2.4231: Reduce the pressure of compressed air to the minimum required $6,933 $480 $4,468
100,784
kWh
$2,243
-
kW-mo/yr
$222
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,846 $8,295 $2,295
51,762
kWh
$475
-
kW-mo/yr
$76
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,473 $4,600 $1,821
41,077
kWh
$592
-
kW-mo/yr
$60
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $531 $1,400 $428
9,661
kWh
$89
-
kW-mo/yr
$14
09 2.2515: Use optimum thickness insulation $286 $886 $277
6,241
kWh
- $9
TOTAL RECOMMENDED $77,608 $144,339 $61,986
1,398,258
kWh
$13,178
-
kW-mo/yr
$2,444
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs