Assessment Year 2012
Principal Product Steel Cans
NAICS 332431: Metal Can Manufacturing
SIC 3411: Metal Cans
Sales Range $10
M
to 50
M
# of Employees 175
Plant Area 135,000
ft2
Annual Production 88,000,000
pieces
Production Hrs. Annual 6,732
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $616,676 9,909,900
kWh
Electricity Demand $231,325 22,346
kW-mo/yr
Electricity Fees $(-90,089.0) -
Natural Gas $179,096 26,585
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $77,671 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,673

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.4224: Upgrade controls on compressors $35,953 $25,000 $29,976
481,694
kWh
$9,253
-
kW-mo/yr
$(-3,276.0) -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,898 $9,195 $10,150
163,103
kWh
$2,857
-
kW-mo/yr
$(-1,109.0) -
03 2.4231: Reduce the pressure of compressed air to the minimum required $24,967 $800 $20,315
335,822
kWh
$6,872
-
kW-mo/yr
$(-2,220.0) -
04 2.7135: Install occupancy sensors $1,775 $2,010 $1,993
32,028
kWh
- $(-218.0) -
05 2.2515: Use optimum thickness insulation $1,260 $1,155 - - - $1,260
-
MMBtu
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,818 $879 $1,524
24,475
kWh
$450
-
kW-mo/yr
$(-156.0) -
TOTAL RECOMMENDED $77,671 $39,039 $63,958
1,037,122
kWh
$19,432
-
kW-mo/yr
$(-6,979.0) $1,260
-
MMBtu
TOTAL IMPLEMENTED $13,673 $11,205 $12,143
195,131
kWh
$2,857
-
kW-mo/yr
$(-1,327.0) -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs