| Assessment Year | 2010 |
|---|---|
| Principal Product | Finished Rugs |
| NAICS | 314110: Carpet and Rug Mills |
| SIC | 2273: Carpets and Rugs |
| Sales Range | less than $500 k |
| # of Employees | 99 |
| Plant Area |
9,999
ft2
|
| Annual Production | 999
units
|
| Production Hrs. Annual | 2,222
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $999,981 | 11,437,480 |
kWh
|
$0.087 |
| Natural Gas | $2,244,243 | 301,512 |
MMBtu
|
$7.44 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $153,368 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,977 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Natural Gas Savings |
|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $45,702 | $105,000 |
$45,702
-
MMBtu
|
|
| 02 | 2.2511: Insulate bare equipment | $4,977 | $2,445 |
$4,977
-
MMBtu
|
|
| 03 | 2.2135: Repair and eliminate steam leaks | $4,643 | $3,840 |
$4,643
-
MMBtu
|
|
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $91,320 | $84,320 |
$91,320
-
MMBtu
|
|
| 05 | 2.2515: Use optimum thickness insulation | $6,726 | $6,485 |
$6,726
-
MMBtu
|
|
| TOTAL RECOMMENDED | $153,368 | $202,090 |
$153,368
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,977 | $2,445 |
$4,977
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs