| Assessment Year | 2026 |
|---|---|
| Principal Product | Flow Control Instruments |
| NAICS | 332721: Precision Turned Product Manufacturing |
| SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 83 |
| Plant Area |
75,000
ft2
|
| Annual Production | 270,000
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $364,534 | 4,945,200 |
kWh
|
$0.074 |
| Electricity Demand | $195,370 | 11,384 |
kW-mo/yr
|
$17.16 |
| Electricity Fees | $44,022 | - |
|
- |
| Natural Gas | $7,702 | 759 |
MMBtu
|
$10.15 |
| TOTAL YEARLY COSTS | $611,628 | |||
| RECOMMENDED SAVINGS* | $236,215 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $140,833 | $2,348,000 |
$118,489
1,607,723
kWh
|
$12,081
-
kW-mo/yr
|
$10,263 | |
| 02 | 2.7232: Replace existing hvac unit with high efficiency model | $74,515 | $413,476 |
$42,882
581,852
kWh
|
$26,203
-
kW-mo/yr
|
$5,430 | |
| 03 | 2.7241: Install outside air damper / economizer on hvac unit | $8,451 | $7,095 |
$7,835
106,315
kWh
|
- | $616 | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,711 | $900 |
$6,085
82,564
kWh
|
$1,064
-
kW-mo/yr
|
$562 | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,749 | $8,591 |
$1,622
22,002
kWh
|
- | $127 | |
| 06 | 2.7135: Install occupancy sensors | $695 | $334 |
$644
8,733
kWh
|
- | $51 | |
| 07 | 2.3212: Optimize plant power factor | $2,261 | $7,518 | - | - | $2,261 | |
| TOTAL RECOMMENDED | $236,215 | $2,785,914 |
$177,557
2,409,189
kWh
|
$39,348
-
kW-mo/yr
|
$19,310 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs