Assessment Year | 2024 |
---|---|
Principal Product | Infiltrator Systems |
NAICS | 326122: Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084: Plastics Pipe |
Sales Range | $5 M to 10M |
# of Employees | 22 |
Plant Area |
42,215
ft2
|
Annual Production | 14,436
thousand feet
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $128,433 | 1,431,702 |
kWh
|
$0.090 |
Electricity Demand | $29,442 | 6,173 |
kW-mo/yr
|
$4.77 |
Electricity Fees | $32,954 | - |
|
- |
Natural Gas | $174,433 | 11,562 |
MMBtu
|
$15.09 |
TOTAL YEARLY COSTS | $365,262 | |||
RECOMMENDED SAVINGS* | $108,172 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $81,410 | $555,652 |
$66,372
739,933
kWh
|
$981
-
kW-mo/yr
|
$14,057 | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,200 | $500 |
$1,608
17,927
kWh
|
$212
-
kW-mo/yr
|
$380 | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,530 | $5,091 |
$1,175
13,098
kWh
|
$91
-
kW-mo/yr
|
$264 | - | |
04 | 2.2437: Recover waste heat from equipment | $6,760 | $8,397 | - | - | - |
$6,760
-
MMBtu
|
|
05 | 2.4239: Eliminate or reduce compressed air usage | $5,137 | $2,005 |
$3,952
44,055
kWh
|
$298
-
kW-mo/yr
|
$887 | - | |
06 | 2.2441: Preheat boiler makeup water with waste process heat | $10,563 | $56,271 | - | - | - |
$10,563
-
MMBtu
|
|
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $224 | $224 |
$140
1,558
kWh
|
$45
-
kW-mo/yr
|
$39 | - | |
08 | 2.7135: Install occupancy sensors | $348 | $452 |
$288
3,212
kWh
|
- | $60 | - | |
TOTAL RECOMMENDED | $108,172 | $628,592 |
$73,535
819,783
kWh
|
$1,627
-
kW-mo/yr
|
$15,687 |
$17,323
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs