Assessment Year | 2024 |
---|---|
Principal Product | Beer |
NAICS | 312120: Breweries |
SIC | 2082: Malt Beverages |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
60,000
ft2
|
Annual Production | 60,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $320,631 | 4,583,442 |
kWh
|
$0.070 |
Electricity Demand | $123,339 | 11,621 |
kW-mo/yr
|
$10.61 |
Electricity Fees | $34,077 | - |
|
- |
Natural Gas | $44,016 | 36,908 |
MMBtu
|
$1.19 |
TOTAL YEARLY COSTS | $522,062 | |||
RECOMMENDED SAVINGS* | $462,996 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 4.111: Add equipment/ operators to reduce production bottleneck | $386,550 | $1,582,496 | - | - | $386,550 | |
02 | 2.9114: Use solar heat to make electricty | $45,995 | $522,500 |
$35,491
710,818
kWh
|
$10,504
-
kW-mo/yr
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $26,223 | $1,293 |
$16,740
239,320
kWh
|
$9,483
-
kW-mo/yr
|
- | |
04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $4,228 | $13,714 |
$4,228
50,056
kWh
|
- | - | |
TOTAL RECOMMENDED | $462,996 | $2,120,003 |
$56,459
1,000,194
kWh
|
$19,987
-
kW-mo/yr
|
$386,550 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs