Assessment Year | 2022 |
---|---|
Principal Product | Automotive Trim |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $50 M to 100M |
# of Employees | 325 |
Plant Area |
293,000
ft2
|
Annual Production | 3,000,000
units
|
Production Hrs. Annual | 6,336
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $767,332 | 13,235,611 |
kWh
|
$0.058 |
Electricity Demand | $122,149 | 29,821 |
kW-mo/yr
|
$4.10 |
Electricity Fees | $71,163 | - |
|
- |
Natural Gas | $1,836 | 124 |
MMBtu
|
$14.81 |
TOTAL YEARLY COSTS | $962,480 | |||
RECOMMENDED SAVINGS* | $59,736 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,826 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $46,023 | $44,464 |
$37,494
646,789
kWh
|
$5,120
-
kW-mo/yr
|
$3,409 | |
02 | 2.7135: Install occupancy sensors | $2,699 | $2,060 |
$2,499
43,110
kWh
|
- | $200 | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,104 | $4,929 |
$3,470
59,865
kWh
|
$330
-
kW-mo/yr
|
$304 | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,910 | $400 |
$5,767
99,475
kWh
|
$631
-
kW-mo/yr
|
$512 | |
TOTAL RECOMMENDED | $59,736 | $51,853 |
$49,230
849,239
kWh
|
$6,081
-
kW-mo/yr
|
$4,425 | ||
TOTAL IMPLEMENTED | $52,826 | $51,453 |
$43,463
749,764
kWh
|
$5,450
-
kW-mo/yr
|
$3,913 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs