Assessment Year | 2022 |
---|---|
Principal Product | Flooring Tiles |
NAICS | 327120: Clay Building Material and Refractories Manufacturing |
SIC | 3253: Ceramic Wall and Floor Tile |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
250,000
ft2
|
Annual Production | 15,000,000
units
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $639,932 | 12,620,120 |
kWh
|
$0.051 |
Electricity Demand | $526,244 | 41,890 |
kW-mo/yr
|
$12.56 |
Electricity Fees | $31,475 | - |
|
- |
Natural Gas | $92,022 | 22,026 |
MMBtu
|
$4.18 |
TOTAL YEARLY COSTS | $1,289,673 | |||
RECOMMENDED SAVINGS* | $63,231 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $60,716 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $50,108 | $47,329 |
$33,490
660,458
kWh
|
$15,301
-
kW-mo/yr
|
$1,317 | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,515 | $12,000 |
$1,833
36,150
kWh
|
$616
-
kW-mo/yr
|
$66 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,608 | $2,502 |
$7,043
138,897
kWh
|
$3,286
-
kW-mo/yr
|
$279 | |
TOTAL RECOMMENDED | $63,231 | $61,831 |
$42,366
835,505
kWh
|
$19,203
-
kW-mo/yr
|
$1,662 | ||
TOTAL IMPLEMENTED | $60,716 | $49,831 |
$40,533
799,355
kWh
|
$18,587
-
kW-mo/yr
|
$1,596 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs