Assessment Year 2021
Principal Product Woodchips
NAICS 322110: Pulp Mills
SIC 2611: Pulp Mills
Sales Range $10
M
to 50
M
# of Employees 10
Plant Area 10,000
ft2
Annual Production 554,677
ton
Production Hrs. Annual 2,080
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $194,108 2,246,400
kWh
Electricity Fees $11,230 -
TOTAL YEARLY COSTS $205,338
RECOMMENDED SAVINGS* $19,785 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,143

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings
01 4.454: Modify startup/shutdown times $17,505 - - $17,505
02 2.3212: Optimize plant power factor $1,608 $7,769 - $1,608
03 2.7142: Utilize higher efficiency lamps and/or ballasts $638 $850 $608
7,032
kWh
$30
04 2.7134: Use photocell controls $34 $112 $32
374
kWh
$2
TOTAL RECOMMENDED $19,785 $8,731 $640
7,406
kWh
$19,145
TOTAL IMPLEMENTED $18,143 $850 $608
7,032
kWh
$17,535