Assessment Year | 2020 |
---|---|
Principal Product | Metal Parts |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
85,280
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 4,940
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $100,104 | 1,426,200 |
kWh
|
$0.070 |
Electricity Demand | $71,278 | 5,455 |
kW-mo/yr
|
$13.07 |
Electricity Fees | $21,168 | - |
|
- |
Natural Gas | $4,668 | 394 |
MMBtu
|
$11.85 |
TOTAL YEARLY COSTS | $197,218 | |||
RECOMMENDED SAVINGS* | $64,633 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,371 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $37,963 | $29,625 |
$23,272
331,563
kWh
|
$10,518
-
kW-mo/yr
|
$4,173 | |
02 | 2.6218: Turn off equipment when not in use | $538 | $121 |
$479
6,828
kWh
|
- | $59 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,318 | $21,905 |
$9,506
135,432
kWh
|
$5,908
-
kW-mo/yr
|
$1,904 | |
04 | 2.3511: Use plant owned transformers or lease transformers | $3,981 | $17,881 |
$(-784.0)
(-11,169)
kWh
|
- | $4,765 | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,885 | $500 |
$1,208
17,215
kWh
|
$470
-
kW-mo/yr
|
$207 | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,948 | $4,200 |
$2,044
29,127
kWh
|
$580
-
kW-mo/yr
|
$324 | |
TOTAL RECOMMENDED | $64,633 | $74,232 |
$35,725
508,996
kWh
|
$17,476
-
kW-mo/yr
|
$11,432 | ||
TOTAL IMPLEMENTED | $5,371 | $4,821 |
$3,731
53,170
kWh
|
$1,050
-
kW-mo/yr
|
$590 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs