Assessment Year | 2016 |
---|---|
Principal Product | rolled steel cut to size |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $50 M to 100M |
# of Employees | 18 |
Plant Area |
110,000
ft2
|
Annual Production | 80,000
ton
|
Production Hrs. Annual | 2,168
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,372 | 870,600 |
kWh
|
$0.080 |
Electricity Fees | $23,006 | - |
|
- |
LPG | $47,452 | 4,212 |
MMBtu
|
$11.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,431 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 4.454: Modify startup/shutdown times | $3,959 | - | - | $3,959 | - | |
02 | 2.7313: Recycle air for heating, ventilation and air conditioning | $1,116 | $1,660 | - | - |
$1,116
-
MMBtu
|
|
03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $201 | $508 | - | - |
$201
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $566 | $2,045 |
$537
6,740
kWh
|
$29 | - | |
05 | 2.7134: Use photocell controls | $414 | $664 |
$393
4,931
kWh
|
$21 | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $175 | $120 |
$166
2,086
kWh
|
$9 | - | |
TOTAL RECOMMENDED | $6,431 | $4,997 |
$1,096
13,757
kWh
|
$4,018 |
$1,317
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs