| Assessment Year | 2016 |
|---|---|
| Principal Product | rolled steel cut to size |
| NAICS | 332322: Sheet Metal Work Manufacturing |
| SIC | 3444: Sheet Metal Work |
| Sales Range | $50 M to 100M |
| # of Employees | 18 |
| Plant Area |
110,000
ft2
|
| Annual Production | 80,000
ton
|
| Production Hrs. Annual | 2,168
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $69,372 | 870,600 |
kWh
|
$0.080 |
| Electricity Fees | $23,006 | - |
|
- |
| LPG | $47,452 | 4,212 |
MMBtu
|
$11.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,431 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | LPG Savings |
|---|---|---|---|---|---|---|---|
| 01 | 4.454: Modify startup/shutdown times | $3,959 | - | - | $3,959 | - | |
| 02 | 2.7313: Recycle air for heating, ventilation and air conditioning | $1,116 | $1,660 | - | - |
$1,116
-
MMBtu
|
|
| 03 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $201 | $508 | - | - |
$201
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $566 | $2,045 |
$537
6,740
kWh
|
$29 | - | |
| 05 | 2.7134: Use photocell controls | $414 | $664 |
$393
4,931
kWh
|
$21 | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $175 | $120 |
$166
2,086
kWh
|
$9 | - | |
| TOTAL RECOMMENDED | $6,431 | $4,997 |
$1,096
13,757
kWh
|
$4,018 |
$1,317
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | LPG Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs