ITAC Assessment: UA0151
ITAC logo
ITAC Assessment: UA0151
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2015
Principal Product Tissue Paper Products
NAICS 322121: Paper (except Newsprint) Mills
SIC 2621: Paper Mills
Sales Range $10
M
to 50
M
# of Employees 485
Plant Area 1,602,967
ft2
Annual Production 185,000
ton
Production Hrs. Annual 8,736
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $8,264,228 273,072,843
kWh
Electricity Demand $6,429,669 419,678
kW-mo/yr
Electricity Fees $(-461,919.0) -
Natural Gas $4,760,052 1,339,682
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $387,409 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $156,830

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.2414: Use waste heat from hot flue gases to preheat $107,877 $42,000 - - - $107,877
-
MMBtu
02 2.2121: Increase amount of condensate returned $48,953 $110,000 - - - $48,953
-
MMBtu
03 2.2414: Use waste heat from hot flue gases to preheat $182,046 $500,000 - - - $182,046
-
MMBtu
04 2.3321: Use steam pressure reduction to generate power $25,377 $93,550 $15,378
508,201
kWh
$10,920
-
kW-mo/yr
$(-921.0) -
05 2.3321: Use steam pressure reduction to generate power $23,156 $85,365 $14,033
463,735
kWh
$9,964
-
kW-mo/yr
$(-841.0) -
TOTAL RECOMMENDED $387,409 $830,915 $29,411
971,936
kWh
$20,884
-
kW-mo/yr
$(-1,762.0) $338,876
-
MMBtu
TOTAL IMPLEMENTED $156,830 $152,000 - - - $156,830
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs