Assessment Year | 2014 |
---|---|
Principal Product | Pressure Treated Woods |
NAICS | 321114: Wood Preservation |
SIC | 2491: Wood Preserving |
Sales Range | $50 M to 100M |
# of Employees | 120 |
Plant Area |
200,000
ft2
|
Annual Production | 7,000
thousand feet
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $436,334 | 5,911,715 |
kWh
|
$0.074 |
Electricity Demand | $120,854 | 24,384 |
kW-mo/yr
|
$4.96 |
Electricity Fees | $58,285 | - |
|
- |
Wood | $538,200 | 280,800 |
MMBtu
|
$1.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $90,510 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,403 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Wood Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $33,943 | $13,395 |
$29,827
404,099
kWh
|
$2,807
-
kW-mo/yr
|
$1,309 | - | |
02 | 2.2511: Insulate bare equipment | $4,189 | $1,583 | - | - | - |
$4,189
-
MMBtu
|
|
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $25,414 | - | - |
$24,434
-
kW-mo/yr
|
$980 | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,531 | $10,336 |
$11,006
149,111
kWh
|
$1,042
-
kW-mo/yr
|
$483 | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $8,665 | $10,900 |
$7,320
99,167
kWh
|
$1,011
-
kW-mo/yr
|
$334 | - | |
06 | 2.4133: Use most efficient type of electric motors | $2,554 | $6,336 |
$2,178
29,056
kWh
|
$278
-
kW-mo/yr
|
$98 | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,339 | $50 |
$1,540
20,861
kWh
|
$709
-
kW-mo/yr
|
$90 | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $875 | $1,522 |
$799
10,823
kWh
|
$42
-
kW-mo/yr
|
$34 | - | |
TOTAL RECOMMENDED | $90,510 | $44,122 |
$52,670
713,117
kWh
|
$30,323
-
kW-mo/yr
|
$3,328 |
$4,189
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,403 | $3,155 |
$2,339
31,684
kWh
|
$751
-
kW-mo/yr
|
$124 |
$4,189
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Wood Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs