| Assessment Year | 2014 |
|---|---|
| Principal Product | Lumber Products |
| NAICS | 333243: Sawmill, Woodworking, and Paper Machinery Manufacturing |
| SIC | 3553: Woodworking Machinery |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
40,000
ft2
|
| Annual Production | 12,000,000
units
|
| Production Hrs. Annual | 2,370
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $344,305 | 4,585,012 |
kWh
|
$0.075 |
| Electricity Demand | $5,669 | 1,196 |
kW-mo/yr
|
$4.74 |
| Electricity Fees | $26,897 | - |
|
- |
| Natural Gas | $1,702 | 127 |
MMBtu
|
$13.40 |
| Wood | $17,766 | 20,727 |
MMBtu
|
$0.86 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $63,779 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,569 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Wood Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1113: Reduce combustion air flow to optimum | $26,427 | $700 |
$5,580
73,714
kWh
|
$498
-
kW-mo/yr
|
$467 |
$19,882
-
MMBtu
|
|
| 02 | 4.454: Modify startup/shutdown times | $13,749 | - | - | - | $13,749 | - | |
| 03 | 2.8112: Combine utility meters | $87 | - | - | - | $87 | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,325 | $12,089 |
$9,682
127,895
kWh
|
$834
-
kW-mo/yr
|
$809 | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,373 | $7,195 |
$4,625
61,101
kWh
|
$364
-
kW-mo/yr
|
$384 | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,196 | $100 |
$3,333
44,027
kWh
|
$563
-
kW-mo/yr
|
$300 | - | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,622 | $654 |
$2,435
32,164
kWh
|
- | $187 | - | |
| TOTAL RECOMMENDED | $63,779 | $20,738 |
$25,655
338,901
kWh
|
$2,259
-
kW-mo/yr
|
$15,983 |
$19,882
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $9,569 | $7,295 |
$7,958
105,128
kWh
|
$927
-
kW-mo/yr
|
$684 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Wood Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs