Assessment Year | 2014 |
---|---|
Principal Product | Metal Furniture |
NAICS | 337124: Metal Household Furniture Manufacturing |
SIC | 2514: Metal Household Furniture |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
750,000
ft2
|
Annual Production | 214,000
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $302,580 | 3,698,041 |
kWh
|
$0.082 |
Electricity Fees | $26,940 | - |
|
- |
Natural Gas | $300,642 | 32,504 |
MMBtu
|
$9.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $99,013 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,136 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $47,063 | $93,733 |
$47,063
563,295
kWh
|
- | |
02 | 2.7145: Install skylights | $31,556 | $40,622 |
$31,556
377,685
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,580 | $1,900 |
$6,580
78,757
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,732 | $800 |
$1,732
20,735
kWh
|
- | |
05 | 2.7231: Use radiant heater for spot heating | $10,526 | $11,550 | - |
$10,526
-
MMBtu
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,556 | $321 |
$1,556
18,624
kWh
|
- | |
TOTAL RECOMMENDED | $99,013 | $148,926 |
$88,487
1,059,096
kWh
|
$10,526
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,136 | $2,221 |
$8,136
97,381
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs