Assessment Year | 2013 |
---|---|
Principal Product | Hydraulic Power Units |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
33,600
ft2
|
Annual Production | 240,000
pieces
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,956 | 873,248 |
kWh
|
$0.094 |
Electricity Demand | $11,015 | 2,740 |
kW-mo/yr
|
$4.02 |
Electricity Fees | $4,265 | - |
|
- |
Natural Gas | $1,879 | 121 |
MMBtu
|
$15.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,920 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,278 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $2,153 | $50 |
$2,071
22,070
kWh
|
- | $82 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,238 | $3,565 |
$1,920
20,460
kWh
|
$233
-
kW-mo/yr
|
$85 | |
03 | 2.7122: Disconnect ballasts | $1,125 | $800 |
$965
10,282
kWh
|
$117
-
kW-mo/yr
|
$43 | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,229 | $400 |
$1,054
11,235
kWh
|
$128
-
kW-mo/yr
|
$47 | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,175 | $2,330 |
$1,024
10,909
kWh
|
$106
-
kW-mo/yr
|
$45 | |
TOTAL RECOMMENDED | $7,920 | $7,145 |
$7,034
74,956
kWh
|
$584
-
kW-mo/yr
|
$302 | ||
TOTAL IMPLEMENTED | $3,278 | $850 |
$3,036
32,352
kWh
|
$117
-
kW-mo/yr
|
$125 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs