| Assessment Year | 2013 |
|---|---|
| Principal Product | steel |
| NAICS | 331110: Iron and Steel Mills and Ferroalloy Manufacturing |
| SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 500 |
| Plant Area |
871,200
ft2
|
| Annual Production | 420,000
ton
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $13,541,667 | 208,333,333 |
kWh
|
$0.065 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $85,561 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $28,182 | $17,526 |
$28,182
433,569
kWh
|
|
| 02 | 2.2691: Shut off cooling if cold outside air will cool process | $38,831 | $7,430 |
$38,831
597,394
kWh
|
|
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $18,548 | $48 |
$18,548
285,352
kWh
|
|
| TOTAL RECOMMENDED | $85,561 | $25,004 |
$85,561
1,316,315
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs