Assessment Year 2012
Principal Product Dried Flowers
NAICS 339999: All Other Miscellaneous Manufacturing
SIC 3999: Manufacturing Industries, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 70
Plant Area 450,000
ft2
Annual Production 225,000
pieces
Production Hrs. Annual 2,295
hrs
Location (State) Alabama

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $90,068 1,069,416
kWh
Electricity Demand $21,517 4,182
kW-mo/yr
Electricity Fees $5,153 -
Natural Gas $77,030 7,050
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $17,044 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,259

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $8,259 $39,310 $6,035
71,657
kWh
$1,880
-
kW-mo/yr
$344 -
02 2.7135: Install occupancy sensors $3,058 $2,513 $2,931
34,800
kWh
- $127 -
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,034 $480 $589
6,995
kWh
$402
-
kW-mo/yr
$43 -
04 2.4231: Reduce the pressure of compressed air to the minimum required $806 $480 $624
7,407
kWh
$148
-
kW-mo/yr
$34 -
05 2.4239: Eliminate or reduce compressed air usage $244 $634 $123
1,459
kWh
$111
-
kW-mo/yr
$10 -
06 2.7231: Use radiant heater for spot heating $1,585 $3,212 - - - $1,585
-
MMBtu
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,356 $2,344 $995
11,820
kWh
$318
-
kW-mo/yr
$43 -
08 2.2136: Install / repair insulation on steam lines $702 $386 - - - $702
-
MMBtu
TOTAL RECOMMENDED $17,044 $49,359 $11,297
134,138
kWh
$2,859
-
kW-mo/yr
$601 $2,287
-
MMBtu
TOTAL IMPLEMENTED $8,259 $39,310 $6,035
71,657
kWh
$1,880
-
kW-mo/yr
$344 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs