| Assessment Year | 2012 |
|---|---|
| Principal Product | Film |
| NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | less than $500 k |
| # of Employees | 10 |
| Plant Area |
1,500,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $354,018 | 5,709,960 |
kWh
|
$0.062 |
| Natural Gas | $903,616 | 180,723 |
MMBtu
|
$5.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $46,622 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,689 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,345 | $7,808 |
$5,345
86,211
kWh
|
- | |
| 02 | 2.7135: Install occupancy sensors | $428 | $1,100 |
$428
6,909
kWh
|
- | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $12,335 | $28,658 | - |
$12,335
-
MMBtu
|
|
| 04 | 2.2511: Insulate bare equipment | $3,261 | $2,173 |
$3,261
52,590
kWh
|
- | |
| 05 | 2.2522: Isolate hot or cold equipment | $25,253 | $12,880 |
$13,576
218,976
kWh
|
$11,677
-
MMBtu
|
|
| TOTAL RECOMMENDED | $46,622 | $52,619 |
$22,610
364,686
kWh
|
$24,012
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,689 | $3,273 |
$3,689
59,499
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs