Assessment Year | 2011 |
---|---|
Principal Product | Communications Equipment |
NAICS | 334290: Other Communications Equipment Manufacturing |
SIC | 3669: Communications Equipment, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 2,000 |
Plant Area |
1,050,000
ft2
|
Annual Production | 500,000
units
|
Production Hrs. Annual | 7,300
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,631,434 | 33,155,832 |
kWh
|
$0.049 |
Electricity Demand | $802,040 | 65,227 |
kW-mo/yr
|
$12.30 |
Electricity Fees | $(-175,039.0) | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,169 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7122: Disconnect ballasts | $47,591 | $5,500 |
$33,656
785,072
kWh
|
$17,923
-
kW-mo/yr
|
$(-3,988.0) | |
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $549 | $845 |
$595
13,885
kWh
|
- | $(-46.0) | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,386 | $2,900 |
$2,802
49,304
kWh
|
$825
-
kW-mo/yr
|
$(-241.0) | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,557 | $80 |
$2,824
49,678
kWh
|
$986
-
kW-mo/yr
|
$(-253.0) | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,086 | $15,744 |
$4,428
103,297
kWh
|
- | $(-342.0) | |
TOTAL RECOMMENDED | $59,169 | $25,069 |
$44,305
1,001,236
kWh
|
$19,734
-
kW-mo/yr
|
$(-4,870.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs