| Assessment Year | 2011 |
|---|---|
| Principal Product | water meters |
| NAICS | 334514: Totalizing Fluid Meter and Counting Device Manufacturing |
| SIC | 3824: Totalizing Fluid Meters and Counting Devices |
| Sales Range | $1 M to 5M |
| # of Employees | 540 |
| Plant Area |
250,000
ft2
|
| Annual Production | 1,900,000
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,645,220 | 26,804,651 |
kWh
|
$0.061 |
| Natural Gas | $138,362 | 18,119 |
MMBtu
|
$7.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $179,253 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $161,149 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,438 | $23,295 |
$10,438
170,057
kWh
|
- | |
| 02 | 2.7135: Install occupancy sensors | $2,938 | $1,003 |
$2,938
47,869
kWh
|
- | |
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $17,580 | $100 |
$17,580
288,205
kWh
|
- | |
| 04 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $28,528 | $3,584 | - |
$28,528
-
MMBtu
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $30,417 | $1,000 |
$30,417
498,643
kWh
|
- | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $53,363 | $3,900 |
$53,363
874,808
kWh
|
- | |
| 07 | 2.4239: Eliminate or reduce compressed air usage | $524 | $202 |
$524
8,583
kWh
|
- | |
| 08 | 2.4323: Use optimum size and capacity equipment | $35,465 | $27,200 |
$35,465
581,398
kWh
|
- | |
| TOTAL RECOMMENDED | $179,253 | $60,284 |
$150,725
2,469,563
kWh
|
$28,528
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $161,149 | $59,982 |
$132,621
2,172,775
kWh
|
$28,528
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs