Assessment Year | 2008 |
---|---|
Principal Product | Latex Gloves |
NAICS | 339113: Surgical Appliance and Supplies Manufacturing |
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 269 |
Plant Area |
180,000
ft2
|
Annual Production | 500,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $366,957 | 6,983,000 |
kWh
|
$0.053 |
Electricity Demand | $56,859 | 11,937 |
kW-mo/yr
|
$4.76 |
Electricity Fees | $24,000 | - |
|
- |
Natural Gas | $1,682,412 | 194,917 |
MMBtu
|
$8.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $191,879 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,370 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,342 | - |
$5,586
107,729
kWh
|
$756
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,878 | $1,500 |
$1,878
32,169
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,199 | $14,155 |
$5,903
105,352
kWh
|
$296
-
kW-mo/yr
|
- | |
04 | 2.7122: Disconnect ballasts | $1,392 | $243 |
$1,226
23,657
kWh
|
$166
-
kW-mo/yr
|
- | |
05 | 2.2135: Repair and eliminate steam leaks | $6,203 | $300 | - | - |
$6,203
-
MMBtu
|
|
06 | 2.2136: Install / repair insulation on steam lines | $4,555 | $2,415 | - | - |
$4,555
-
MMBtu
|
|
07 | 2.2425: Use flue gases to heat process or service water | $98,000 | $126,000 | - | - |
$98,000
-
MMBtu
|
|
08 | 2.4323: Use optimum size and capacity equipment | $24,566 | $23,000 | - | - |
$24,566
-
MMBtu
|
|
09 | 2.2437: Recover waste heat from equipment | $42,744 | $45,700 | - | - |
$42,744
-
MMBtu
|
|
TOTAL RECOMMENDED | $191,879 | $213,313 |
$14,593
268,907
kWh
|
$1,218
-
kW-mo/yr
|
$176,068
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,370 | $4,458 |
$8,690
163,555
kWh
|
$922
-
kW-mo/yr
|
$10,758
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs