| Assessment Year | 2026 |
|---|---|
| Principal Product | Valves and Components |
| NAICS | 332919: Other Metal Valve and Pipe Fitting Manufacturing |
| SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 45 |
| Plant Area |
40,000
ft2
|
| Annual Production | 103,636
units
|
| Production Hrs. Annual | 4,940
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $62,522 | 750,450 |
kWh
|
$0.083 | |
| Electricity Demand | $28,857 | 2,677 |
kW-mo/yr
|
$10.78 | |
| Natural Gas | $12,798 | 1,108 |
MMBtu
|
$11.55 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,198 | 146 |
Tgal
|
$8.21 | |
| Water Disposal | $1,477 | 146 |
Tgal
|
$10.12 | |
| TOTAL YEARLY COSTS | $106,852 | ||||
| RECOMMENDED SAVINGS* | $50,362 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $35,136 | $290,400 |
$35,136
421,805
kWh
|
- | - | - | |
| 02 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $4,582 | $1,265 | - | - |
$4,582
-
MMBtu
|
- | |
| 03 | 2.7231: Use radiant heater for spot heating | $3,466 | $20,800 | - | - |
$3,466
-
MMBtu
|
- | |
| 04 | 2.4312: Improve lubrication practices | $2,776 | $4,213 | - | - | - | $2,776 | |
| 05 | 2.7232: Replace existing hvac unit with high efficiency model | $2,185 | $12,000 |
$1,057
12,689
kWh
|
- |
$128
-
MMBtu
|
$1,000 | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $1,162 | $3,300 |
$1,162
13,959
kWh
|
- | - | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,055 | $1,500 |
$796
9,556
kWh
|
$259
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $50,362 | $333,478 |
$38,151
458,009
kWh
|
$259
-
kW-mo/yr
|
$8,176
-
MMBtu
|
$3,776 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs